library / browse / spatial variable
Spatial variable, 17 records
Ventilation rate
Outdoor air delivery or air-change rate
family: Air
ND-0003 · 2023 · Systematic review and meta-analysis
Short-term exposure to indoor carbon dioxide and cognitive task performance: A systematic review and meta-analysis
Fan et al. Building and Environment
Short-term CO2 exposures below 5000 ppm were associated with cognitive effects in the pooled literature, with complex tasks appearing more sensitive.
ND-0004 · 2012 · Controlled exposure study
Is CO2 an Indoor Pollutant? Direct Effects of Low-to-Moderate CO2 Concentrations on Human Decision-Making Performance
Satish et al. Environmental Health Perspectives
Decision-making scores declined at higher CO2 exposures in several domains, with larger effects at 2500 ppm.
ND-0005 · 2016 · Controlled crossover study
Associations of Cognitive Function Scores with Carbon Dioxide, Ventilation, and Volatile Organic Compound Exposures in Office Workers
Allen et al. Environmental Health Perspectives
Cognitive scores were higher under lower-VOC and higher-ventilation conditions than under conventional office conditions.
ND-0006 · 2017 · Review
Ten questions concerning thermal and indoor air quality effects on the performance of office work and schoolwork
Wargocki & Wyon. Building and Environment
Synthesizes evidence that temperature and air quality can influence work and school performance, with effects dependent on task and exposure.
ND-0077 · 2008 · Systematic review
A Review of the Research Literature on Evidence-Based Healthcare Design
Ulrich et al. HERD
The review found design-relevant evidence across infection control, acoustics, nature/daylight, ergonomics, room type and layout, while quality varied by topic.
ND-0097 · 2025 · Standard
ANSI/ASHRAE Standard 62.1-2025: Ventilation and Acceptable Indoor Air Quality
ASHRAE. ASHRAE
Specifies minimum ventilation and IAQ requirements for mechanical and natural ventilation systems.
ND-0098 · 2025 · Standard
ANSI/ASHRAE Standard 62.2-2025: Ventilation and Acceptable Indoor Air Quality in Residential Buildings
ASHRAE. ASHRAE
Defines residential ventilation and source-control requirements, including updated filtration provisions.
ND-0168 · 2017
The impact of working in a green certified building on cognitive function and health
MacNaughton P et al. Building and Environment
Workers in green-certified high-performing buildings scored 26.4% higher on cognitive tests and had 30% fewer sick building symptoms than workers in matched non-certified buildings (n = 109).
ND-0169 · 2021
Associations between acute exposures to PM2.5 and carbon dioxide indoors and cognitive function in office workers: a multicountry longitudinal prospective observational study
Laurent JGC et al. Environmental Research Letters
In about 300 workers across six countries over a year, higher indoor PM2.5 and CO2 were associated with slower and less accurate responses on cognitive tests.
ND-0601 · 2001 · Foundational theory
The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutants
Klepeis NE, Nelson WC, Ott WR, et al. Journal of Exposure Analysis and Environmental Epidemiology
ND-0639 · 2019 · Foundational theory
Outdoor Air Pollution and Brain Structure and Function From Across Childhood to Young Adulthood: A Methodological Review of Brain MRI Studies
Herting, Younan, Campbell et al. Frontiers in Public Health
ND-0671 · 1984
The sick building syndrome: prevalence studies
Finnegan MJ, Pickering CAC, Burge PS. BMJ
Across nine offices doing similar clerical work, workers in air-conditioned buildings reported significantly more nasal, eye and mucous membrane symptoms, lethargy, dry skin and headaches than workers in naturally ventilated ones.
ND-0672 · 1999
Association of Ventilation Rates and CO2 Concentrations with Health and Other Responses in Commercial and Institutional Buildings
Seppänen OA, Fisk WJ, Mendell MJ. Indoor Air
Across studies of about 30,000 office occupants, ventilation below 10 L/s per person went with worse health or perceived air quality in almost every study, with further gains up to about 20 L/s per person.
ND-0673 · 2000
Risk of Sick Leave Associated with Outdoor Air Supply Rate, Humidification, and Occupant Complaints
Milton DK, Glencross JM, Walters MD. Indoor Air
Among 3,720 employees in 40 buildings, office workers with lower outdoor air supply (about 12 L/s per person against 24) had 1.53 times the rate of short-term sick leave.
ND-0674 · 2000
The effects of outdoor air supply rate in an office on perceived air quality, sick building syndrome (SBS) symptoms and productivity
Wargocki P et al. Indoor Air
In a real office ventilated at 3, 10 or 30 L/s per person, more outdoor air reduced dissatisfaction with the air and symptoms, and office task performance rose by about 1.7% for each doubling of ventilation.
ND-0675 · 2011
Ventilation rates and health: multidisciplinary review of the scientific literature
Sundell J, Levin H, Nazaroff WW, et al. Indoor Air
A multidisciplinary review of 27 studies found higher office ventilation, up to about 25 L/s per person, associated with fewer sick building symptoms, and lower rates linked to inflammation, respiratory infections, asthma symptoms and short-term sick leave.
ND-0676 · 2016
Effects of exposure to carbon dioxide and bioeffluents on perceived air quality, self-assessed acute health symptoms, and cognitive performance
Zhang X, Wargocki P, Lian Z, Thyregod C. Indoor Air
Pure CO2 added up to 3,000 ppm had no significant effect on perceived air quality, symptoms or cognitive performance. When CO2 reached 3,000 ppm through human bioeffluents, symptoms rose and performance fell.