library / browse / spatial variable
Spatial variable, 7 records
CO2 concentration
Indoor carbon dioxide concentration and proxy role
family: Air
ND-0003 · 2023 · Systematic review and meta-analysis
Short-term exposure to indoor carbon dioxide and cognitive task performance: A systematic review and meta-analysis
Fan et al. Building and Environment
Short-term CO2 exposures below 5000 ppm were associated with cognitive effects in the pooled literature, with complex tasks appearing more sensitive.
ND-0004 · 2012 · Controlled exposure study
Is CO2 an Indoor Pollutant? Direct Effects of Low-to-Moderate CO2 Concentrations on Human Decision-Making Performance
Satish et al. Environmental Health Perspectives
Decision-making scores declined at higher CO2 exposures in several domains, with larger effects at 2500 ppm.
ND-0005 · 2016 · Controlled crossover study
Associations of Cognitive Function Scores with Carbon Dioxide, Ventilation, and Volatile Organic Compound Exposures in Office Workers
Allen et al. Environmental Health Perspectives
Cognitive scores were higher under lower-VOC and higher-ventilation conditions than under conventional office conditions.
ND-0139 · 2026 · Laboratory experiment (split-plot) with lab-versus-classroom comparison
Combined effects of acoustics and indoor air quality on calculation performance: a laboratory experiment and a lab-dilemma investigation
Matteo Pellegatti, Chiara Visentin, Simone Torresin, Francesco Babich, Nicola Prodi. Frontiers in Built Environment, vol. 12
Pupils solved arithmetic in a room held at 800 or 2000 ppm CO2 (pure CO2, between subjects) under five sound conditions: quiet, playground, birdsong and two ventilation-noise levels (47 to 52 dB(A)). CO2 had no effect on accuracy or speed, and there was no CO2 by sound interaction. Sound affected response time only, and only for mid noise-sensitivity pupils; lab responses were 0.9 to 1.6 s faster than in real classrooms and sounds ranked differently across the two settings.
ND-0169 · 2021
Associations between acute exposures to PM2.5 and carbon dioxide indoors and cognitive function in office workers: a multicountry longitudinal prospective observational study
Laurent JGC et al. Environmental Research Letters
In about 300 workers across six countries over a year, higher indoor PM2.5 and CO2 were associated with slower and less accurate responses on cognitive tests.
ND-0672 · 1999
Association of Ventilation Rates and CO2 Concentrations with Health and Other Responses in Commercial and Institutional Buildings
Seppänen OA, Fisk WJ, Mendell MJ. Indoor Air
Across studies of about 30,000 office occupants, ventilation below 10 L/s per person went with worse health or perceived air quality in almost every study, with further gains up to about 20 L/s per person.
ND-0676 · 2016
Effects of exposure to carbon dioxide and bioeffluents on perceived air quality, self-assessed acute health symptoms, and cognitive performance
Zhang X, Wargocki P, Lian Z, Thyregod C. Indoor Air
Pure CO2 added up to 3,000 ppm had no significant effect on perceived air quality, symptoms or cognitive performance. When CO2 reached 3,000 ppm through human bioeffluents, symptoms rose and performance fell.