library / browse / ND-0003

ND-0003 · 2023 · Meta-analysis

HighDirect built environment

Short-term exposure to indoor carbon dioxide and cognitive task performance: A systematic review and meta-analysis

Fan et al. Building and Environment. 2023.

doi.org/10.1016/j.buildenv.2023.110331 · Source details checked

Source details checked refers to publication information or an official source page. See the record’s limitations for incomplete extraction and the method for how to read the labels.

What the source reports

Short-term CO2 exposures below 5000 ppm were associated with cognitive effects in the pooled literature, with complex tasks appearing more sensitive.

Limitations

CO2 can be both an exposure and a ventilation proxy; protocols and task batteries differ substantially.

NEURODESIGN reading

The design story is not 'CO2 makes people stupid.' It is that stale occupied rooms can become cognitively expensive, and complex work may reveal the cost first.

Design questions and applications

Use CO2 as an operational signal for occupancy and ventilation, while avoiding claims that one universal ppm value is a direct brain threshold.

Study design

Systematic review and meta-analysis; 15 eligible studies

Participants or population

Healthy human participants

Setting

Controlled indoor exposures

Field

Indoor air quality

Process investigated

CO2 exposure, cognitive performance

Design variable

Ventilation, indoor CO2

Keywords

CO2, ventilation, cognition, air quality